| Model |
SUN-7K-SG05LP1-EU-SM2 |
SUN-7.6K-SG05LP1-EU |
SUN-8K-SG05LP1-EU-SM2 |
SUN-10K-SG05LP1-EU-SM2 |
| Battery Input Data |
|
| Battery Type |
Lead-acid or Lithium-ion
|
| Battery Voltage Range(V) |
40-60
|
| Max.Charging Current(A) |
175 |
190 |
190 |
210 |
| Max.Discharging Current(A) |
175 |
190 |
190 |
210 |
| Charging Strategy for Li-ion Battery |
Self-adaption to BMS
|
| Number of battery input |
1
|
| PV String Input Data |
|
|
Max. PV Access Power (W)
|
14000 |
15200 |
16000 |
20000 |
| Max PV Input Power(W) |
11200 |
12160 |
12800 |
16000 |
| Max PV Input Voltage(V) |
500
|
| Start-up Voltage(V) |
125
|
| MPPT Voltage Range(V) |
150-425
|
| Rated PV Input Voltage(V) |
370
|
| Max Input Short-Circuit Current(A) |
34+34
|
| Max Operating PV Input Current(A) |
26+26
|
| No.of MPP Trackers/No.of String Per MPP Tracker |
2/2+2
|
| AC Input/Output Data |
|
|
| Rated AC Input/Output Active Power(W) |
7000 |
7600 |
8000 |
10000 |
| Max AC Input/Output Apparent Power (VA) |
7700 |
8360 |
8800 |
11000 |
| Peak Power (off-grid)(W) |
2 times of rated power,10s
|
| Rated AC Input/Output Current(A) |
31.9/30.5 |
34.5/33.1 |
36.4/34.8 |
45.5/43.5 |
| Max AC Input/Output Current(A) |
35/33.5 |
38/36.4 |
40/38.3 |
50/47.9 |
| Max Continuous AC Passthrough (grid to load)(A) |
50
|
| Rated Input/Output Voltage/Range(V) |
220V/230 0.85Un-1.1Un
|
| Grid Connection Form |
L+N+PE
|
| Rated Input/Output Grid Frequency/Range |
50Hz/45Hz-55Hz 60Hz/55Hz-65Hz
|
| Power Factor Adjustment Range |
0.8 leading-0.8lagging
|
| Total Current Harmonic Distortion THDi |
<3% (of nominal power)
|
| DC Injection Current |
<0.5%ln
|
| Efficiency |
|
| Max Efficiency |
97.6%
|
| Euro Efficiency |
96.5%
|
| MPPT Efficiency |
>99%
|
| Equipment Protection |
|
|
Integrated
|
DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
|
| Surge Protection Level |
TYPE II(DC),TYPE II(AC)
|
| Interface |
|
| Communication Interface |
RS485/RS232/CAN |
|
Monitor Mode
|
GPRS/WIFI/Bluetooth/4G/LAN(optional) |
| General Data |
|
| Operating Temperature Range |
-40 to +60℃, >45℃ Derating
|
| Permissible Ambient Humidity |
0~100%
|
| Permissible Altitude |
2000m
|
| Noise |
<30 dB(A)
|
| Ingress Protection(IP) Rating |
IP 65
|
| Inverter Topology |
Non-Isolated
|
| Over Voltage Category |
OVC II(DC),OVC III(AC)
|
| Cabinet size(W*H*D)[mm] |
366×589.5×237 (Excluding Connectors and Brackets)
|
| Weight[kg] |
26.8
|
| Warranty |
5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
|
| Type Of Cooling |
Intelligent air cooling
|
| Grid Regulation |
IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
|
| Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
|