Model |
SUN-60K-G04P3-EU-AM4 |
SUN-70K-G04P3-EU-AM4 |
SUN-75K-G04P3-EU-AM4 |
SUN-80K-G04P3-EU-AM4 |
PV String Input Date |
|
Max. PV Input Power(kW) |
90 |
105 |
112.5 |
120 |
Max. PV Input Voltage(V) |
1100 |
Start-up Voltage(V) |
250 |
MPPT voltage range(V) |
200-1000 |
Rated PV Input voltage(V) |
600 |
720 |
Max. Input Short Circuit Current (A) |
60+60+60+60 |
Max. Operating PV Input Current(A) |
40+40+40+40 |
No. of MPP Trackers/ No. of Strings MPP Tracker |
4/3+3+3+3 |
4/4+4+4+4 |
AC Output Side |
|
Rated AC Output Active Power (kW) |
60 |
70 |
75 |
80 |
Max. AC Output Apparent Power (kVA) |
66 |
77 |
82.5 |
88 |
Rated AC Output Current (A) |
90.9/87 |
106.1/101.5 |
113.6/108.7 |
121.2/115.9 |
Max. AC Output Current (A) |
100/95.7 |
116.7/111.6 |
125/119.6 |
133.3/127.5 |
Rated Output Voltage/Range (V) |
220/380V, 230/400V 0.85Un-1.1Un |
Grid Connection Form |
3L+N+PE |
Rated Output Grid Frequency/range(Hz) |
50Hz/45Hz-55Hz 60Hz/55Hz-65Hz |
Power Factor Adjustment Range |
0.8 leading to 0.8lagging |
Total Current Harmonic Distortion THDi |
<3% |
DC Injection Current |
<0.5%ln |
Efficiency |
|
Max. Efficiency |
98.60% |
98.70% |
Euro Efficiency |
98.00% |
98.10% |
MPPT Efficiency |
>99% |
Equipment Protection |
|
DC Polarity Reverse Connection Protection |
yes |
AC Output Overcurrent Protection |
yes |
AC Output Overvoltage Protection |
yes |
AC Output Short Circuit Protection |
yes |
Thermal Protection |
yes |
DC Terminal Insulation Impedance Monitoring |
yes |
DC Component Monitoring |
yes |
Ground Fault Current Monitoring |
yes |
Arc Fault Circuit Interrupter (AFCI) |
Optional |
Power Network Monitoring |
yes |
Island Protection Monitoring |
yes |
Earth Fault Detection |
yes |
Overvoltage Load Drop Protection |
yes |
Residual Current (RCD) Detection |
yes |
Surge Protection Level |
TYPE II(DC),TYPE II(AC) |
Interface |
|
Communication Interface |
RS485/RS232 |
Monitor Mode |
GPRS/WIFI/Bluetooth/4G/LAN(optional) |
General Data |
|
Operating Temperature Range (°C) |
-25 to +60℃, >45℃ Derating |
Permissible Ambient Humidity |
0~100% |
Permissible Altitude (m) |
4000m |
Noise (dB) |
≤ 55 |
Ingress Protection(IP) Rating |
IP 65 |
Inverter Topology |
Non-Isolated |
Over Voltage Category |
OVC II(DC),OVC III(AC) |
Cabinet Size (WxHxD mm) |
698×613×236.5 (Excluding Connectors and Brackets) |
Weight [kg] |
53.7 |
Warranty [year] |
5 years |
Type Of Cooling |
Intelligent air cooling |
Grid Regulation |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |